Final Report on Life Testing of the Vapor Compression Distillation/Urine Processing Assembly (VCD/UPA) at the Marshall Space Flight Center (1993 to 1997)

NASA/TM-208539, Wieland, P. and Hutchens, C. and Long, D. and Salyer*, B., Final Report on Life Testing of the Vapor Compression Distillation/Urine Processing Assembly (VCD/UPA) at the Marshall Space Flight Center (1993 to 1997), Structures & Dynamics Laboratory, Science and Engineering Directorate, NASA Marshall Space Flight Center, AL 35812 and *Ion Electronics, Huntsville, Alabama, August 1998, pp. 76, Format(s): PDF 2948k

View PDF
- Requires Adobe Acrobat Reader or other PDF viewer.

Wastewater and urine generated on the International Space Station will be processed to recover pure water using vapor compression distillation (VCD). To verify the long-term reliability and performance of the VCD Urine Processor Assembly (UPA), life testing was performed at the Marshall Space Flight Center (MSFC) from January 1993 to April 1996. Two UPA's, the VCD-5 and VCD-5A, were tested for 204 days and 665 days, respectively. The compressor gears and the distillation centrifuge drive belt were found to have operating lives of approximately 4,800 hours, equivalent to 3.9 years of operation on ISS for a crew of three at an average processing rate of 1.76 kg/h (3.87 lb/h). Precise alignment of the flex-splines of the fluids and purge pump motor drives is essential to avoid premature failure after about 400 hours of operation. Results indicate that, with some design and procedural modifications and suitable quality control, the required performance and operational life can be met with the VCD/UPA
Keywords:ecls, vcd, urine processor, upa, life support, international space station
Subjects:Life Sciences: Man/Systems Technology and Life Support: Life Support Systems
ID Code:437
Deposited On:22 July 2002